AIMS Attachment A: AIMS Statement of Work
Page 92 of 130
configuration is provided. RAID shall not be implemented via the
operating system, but by a hardware controller. Disk arrays shall have
open frames to allow the capacity to be doubled by addition of RAID
drives without system shutdown. At least one drive per array should be
in hot standby with automatic failover controlled by the RAID controller.
7. Monitor: Shared rack-mounted monitor per rack (provide rack-
mounted input switching device). The monitor provided shall meet the
requirements provided under the section titled AIMS Monitors.
8. Servers shall be configured to meet or exceed the minimum hardware
requirements detailed below and also meet or exceed the
performance, operational, and functional requirements of this
Specification.
B. File Server Requirements
1. Two (2) 2.8 GHz processors (latest version) with 1MB cache.
Architecture should be Intel or RISC as required by the operating
system.
2. 1 GB DDR2 400 MHz RAM. Sufficient memory shall be provided to
meet the maximum transaction load and ensure the memory is never a
restriction on system performance
3. Minimum 72 GB useable internal hardware RAID 5 disk storage
(10,000 rpm)
4. Two (2) NICs (server-class card) for LAN connection (coordinate
network requirements with network administrator)
5. Minimum 72 GB internal Tape Backup Unit with SCSI card and back
up software
6. 24X IDE CD-RW/DVD ROM drive
7. Remote Access Card
8. Multiple hot-pluggable redundant power supplies
9. Standard windows keyboard and USB 2-button wheel mouse
10. Minimum of two (2) USB 2.0 ports
C. Application Server Requirements
1. Two (2) 3.2 GHz processors (latest version) with 1MB cache.
Architecture should be Intel or RISC as required by the operating
system.