AIMS Attachment A: AIMS Statement of Work
Page 66 of 130
2. Additionally, upon such a failure, the system administrator shall receive
a warning message on the system administrator workstation and an e-
mail, pager, or text message notification, notifying him of the failure.
Server failure shall include any hardware or software based failure.
Should a DDC fail, the system shall immediately notify the system
administrator via the EVIDS management system. The
CONTRACTOR is responsible for providing all hardware, software,
and WAN/PSTN access necessary to support the notification functions.
3. Each DDC shall have remote administration and monitoring
capabilities. This capability shall allow the specific machine to be
remotely configured and to provide a status report to the management
system. Data included in the reporting capabilities shall include: data
pertaining to the machine's memory, storage devices, network
connections, and general health of the machine.
4. All failures of the system shall be logged at a central control point (i.e.,
EVIDS Application Server). The failure shall initiate alarms and reports
(e.g., time and date of failure event). In the event that a workstation
component goes out of service, the central control log shall be
updated. Therefore, where practical, a positive relationship (e.g.,
system heart beat) shall exist between all components of the systems
at all times.
3.4.9 EVIDS Performance Requirements
A. In addition to the performance requirements listed in Section 3.10, the
EVIDS shall conform to the following:
1. The system shall be capable of supporting all DDCs and display
devices as specified in this document within the performance
requirements as outlined herein.
2. In the event of a failure of a DDC that is used to control a display within
a public display bank, the system shall automatically reconfigure the
page displays within the display bank to ensure that the flight
information that was to be displayed on the failed DDC/monitor is
displayed on other monitors. In the instance of a DDC failure, the
system shall automatically reconfigure the timing window, or utilize
another mechanism, to ensure that no gaps in the displayed flight
information are present. For example, if a DDC supporting a display
showing flights from 10:15 AM to 10:45 AM fails, the system shall
reconfigure the displays such that the other DDCs display the flights
during this time period.